10kV VT Voltage Transformer

10kV VT Voltage Transformer

Model:JDZ10-10 Indoor Cast Resin Voltage Transformer
Rated Ratio:10/√3:0.1/√3:0.1/3kV
Insulation Level:12/42/75kV
Rated frequency:50/60Hz
Accuracy Class:0.2/3P,0.5/3P
Rated burden:15VA/30VA for metering,50VA for protection
Standard:GB/T 20840.3 and IEC 61869-3
Send Inquiry
Description
Technical Parameters

Shaanxi Longxiang Electrical Co., Ltd. is one of the most reliable manufacturers and suppliers of 10kv vt voltage transformer in China. With abundant experience, we are committed to providing high quality customized products with competitive price. Welcome to buy premium 10kv vt voltage transformer made in China here from our factory.

 

Products Description

 

JDZ10 series voltage transformers are indoor type, mostly using epoxy resin vacuum casting semi-enclosed or fully enclosed structure, suitable for power systems with rated frequency of 50Hz/60Hz and rated voltage of 10kV and below. They can convert high voltage into low voltage for energy metering, voltage monitoring and relay protection, provide accurate voltage signals for measurement and protection equipment, ensure safe and stable operation of the system, and comply with relevant electrical standards.

 

Model Meaning

 

Model: JDZ10-10 Indoor Cast Resin Voltage Transformer

Rated Ratio: 10/√3 : 0.1/√3 : 0.1/3 kV

Insulation Level: 12/42/75kV

Rated frequency: 50/60Hz

Accuracy Class: 0.2/3P, 0.5/3P

Rated burden: 15VA /30VA for metering, 50VA for protection

Standard:GB/T 20840.3 and IEC 61869-3

JDZ10-10 Voltgae transformer model meaning

 

 

 

Normal Service Condition

Installation site: Indoor

Ambient temperature: Maximum air temperature 40°C; Minimum temperature is -5°C; The daily average temperature does

not exceed 30°C

Relative humidity: The average humidity of a day should be no more than 95%.

                             The average humidity of a month should be no more than 90%.
Earthquake intensity: not exceed 8 degrees.

Atmospheric conditions: There is no severe pollution in the atmosphere

 

Main Technical Parameters

Product Model

Rated voltage ratio (V)

Accuracy class and rated output (VA) COSФ=0.8

Maximum output

Rated insulation level

0.2

0.5

1

3P

3P

6P

   

JDZ10-10

6000/100

15

30

60

50

50

200

7.2/32/60

10000/10

15

30

60

50

50

200

12/42/75

 

Note: Can be customized to your requirements. The above data is standard. For customized options, please feel free to contact us.

 

Product Features

 

1.Excellent Insulation:Epoxy resin-cast insulation with fully - enclosed or semi-enclosed structure. Boasts excellent insulation performance, high impulse voltage resistance, moisture resistance, and corrosion resistance, suitable for harsh environments.


2.High Accuracy: Available in different accuracy classes (e.g., 0.2S, 0.5, etc.), providing precise voltage signals for metering and protection devices.
Compact Structure:Small size, light weight, easy to install. Flexible for various indoor installation spaces and directions.


3.Functional Adaptability:Suitable for power systems with rated voltage of 10kV and below. Enables voltage measurement, energy metering, and provides reliable voltage signals for relay protection. Some models feature overload, short-circuit protection functions.


4.Safe and Reliable:Complies with relevant electrical standards. Stable mechanical strength and insulation performance ensure system operation safety. Terminal boxes of some models have anti-tampering designs.

 

voltage transformer                      voltage transformer 002

 

faq
 

Q:1.What is JDZ10-10 voltage transformer?

A:JDZ10-10 is an indoor, single-phase, epoxy resin cast voltage transformer, designed for 10kV power system. It steps down the primary voltage to 100V for measurement and metering purposes.

Q:2.What is the difference between JDZ10-10 and JDZX10-10?

A:JDZ10-10: Two windings only (primary + secondary). No residual winding. Used for voltage measurement and metering. Cannot detect earth fault.

JDZX10-10: Three windings (primary + secondary + residual/zero-sequence winding). The "X" means residual winding. Used for insulation monitoring and earth fault protection.

Q:3.What is the insulation level?

A:Insulation level is 12 / 42 / 75 kV

 

Q:4.What is the maximum output?

A:It's typically 200VA, which means the transformer can withstand short-term overload without overheating.

Q:5.Where is JDZ10-10 used?

A: It's widely used in: 10kV switchgear (KYN28-12, XGN, etc.)

Voltage measurement panels;Metering cabinets (without earth fault monitoring requirement);Power distribution rooms, industrial plants, commercial buildings

Q:6.What is the minimum order quantity (MOQ)?

A:MOQ is 10 pieces for standard models. 

 

 

 

 

 

 

Send Message